DocumentsAppendixSep 8, 2026Page 1
SITE / MAIN FLOOR PLAN
Site and main-floor plan for a development proposal at 2645/2639 Sooke Road. The drawing shows building access, vehicle circulation, parking, loading, setbacks, and site features.
Key facts
- Project address: 2645/2639 Sooke Road, Langford, BC
- Owners: Paris Fru and Hoa Manh Vu
- Status: DP Application
- Scale: 1:125
- All parking stalls to have Level 2 EV charger rough-in
SITE / MAIN FLOOR PLAN
Project: PROPOSED MIXED-USE DEVELOPMENT
Scale: 1:125
Sheet No.: A2.01


Space Legend
- Residential Lobby
- Parking Lot
- Vehicular Circulation
- CRU
Project Information
| Field | Information |
|---|---|
| Project Address | 2645/2639 SOOKE RD, LANGFORD, BC |
| Owner | Paris Fru & Hoa Manh Vu |
| Total Sheets | 13 |
| Drawn By | SS |
| Checked By | RD |
| Reviewed By | RD |
| Status | DP Application |
| AHJ | City of Langford |
| Sheet Title | SITE / MAIN FLOOR PLAN |
Revision History
| No. | Date | Issue Notes |
|---|---|---|
| A | 2020-5-21 | Pre-Application |
| B | 15-12-21 | Pre-Application |
| C | 21-02-21 | Pre-Application |
| D | 21-03-22 | DP Application |
| E | 10-05-22 | Amended Application |
| F | 03-08-22 | Coordination |
| G | 13-05-26 | DP Resubmission |
| H | 10-06-26 | DP Resubmission |
Site and Plan Annotations
- Building Line Above
- Potential Road Dedication
- 3.00m ROAD DEDICATION
- PROPERTY LINE
- SETBACK LINE
- SETBACK
- 6000mm SETBACK
- 6000mm
- 4500mm
- 3000mm
- 7500mm
- 7500mm
- 3500mm
- 2600mm
- 4500mm
- 2600mm
- 2600mm
- 2600mm
- 4500mm
- 6700mm
- 4500mm
- 6700mm
- 5500mm
- 6700mm
- FLEXIBLE CRU
- RESIDENTIAL LOBBY
- DRIVE AISLE — 6.70m
- DRIVE AISLE — 6.70m
- DRIVEWAY — 6.70m
- PMT
- 15% SLOPE
- TRELLIS ABOVE RAMP
- ENTRANCE PLAZA
- BUILDING ABOVE
- SOOKE ROAD
- FFE 73.05
- 5% SLOPE
- RAMP TO PARKADE BELOW
- LOADING BAY
- OUTLINE OF PARKADE BELOW
- GARBAGE STAGING AREA
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
- SMALL CAR
Plan scale bar: 0, 2, 4, 6, 8, 10 M
Note:
All parking stalls shall be provided
with Level 2 EV charger rough-in.
Existing Site Labels and Measurements
- No. 2639
- No. 2645
- Plan 6534
- Plan 14912
- Plan 15611
- Plan 28306
- Strata Plan 1431
- Plan 41825
- Plan 41825
- gravel driveway
- driveway
- driveway
- deck
- measurements are to building exterior
- measurements are to building exterior
Survey and Site Data
Survey labels: fir; fir; fir; fir; fir; fir; decid; fir; fir; decid; WM; WM; FH; PH; PH
Measurements and elevations:
32, 20; 60; 92; 120; 74; 50; 70, 48; 62; 80; 3.3; 3.3; 9.8; 2.1; 2.5; 1.4; 3.9; 4.2; 3.35; 72.53; 73.28; 73.28; 73.31; 73.28; 73.23; 73.23; 73.22; 73.29; 73.19; 72.82; 72.72; 73.01; 73.14; 73.37; 73.22; 73.18; 73.26; 73.13; 73.18; 73.23; 73.33; 73.28; 73.29; 73.22; 73.27; 73.20; 73.18; 73.16; 73.03; 73.03; 72.92; 72.89; 72.90; 73.08; 73.09; 73.01; 73.00; 72.88; 72.81; 72.78; 72.91; 72.86; 72.97; 73.08; 72.76; 72.79; 72.86; 73.30; 73.17; 72.90; 72.86; 73.11; 73.28; 73.08; 73.04; 73.02; 73.02; 73.14; 73.22; 73.21; 73.1; 73.30; 73.31; 73.29; 73.31; 73.35; 73.19; 73.22; 73.25; 73.30; 72.73; 72.64; 72.49; 72.43; 72.27; 72.32; 72.31; 72.23; 72.06; 72.26; 71.72; 71.79; 71.94; 72.11; 72.44; 72.30; 72.84; 73.19; 72.38; 72.21; 72.55; 72.30; 72.63; 72.88; 72.93; 72.79; 72.61; 72.41; 72.12; 72.58; 72.52; 72.67; 72.80; 72.71; 72.65; 72.61; 72.92; 73.09; 73.11; 73.21; 72.84; 72.94; 73.10; 73.17; 72.62; 72.55; 72.97; 72.95
Site dimensions: 65; 49.35; 48.10; 2.13; 59.43; 2.46; 32.97; 44.13; 24.14; 34.01; 54.50; 10.48; 13.84
Numbered plan labels: 8, 9, 1, 2, 3, 4, 5, 6, 7, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 1, 10, 11, 12, 13, 14, 1, 33, 34, 35, 36, 28, 29, 30, 31, 32
Drawing Note
These Drawings and the design are and at all times remain the exclusive property
of Architecture Panel Inc. and cannot be used without the Landscape Acrhitects's
written consent.Contractor is responsible for verification of all dimensions,
elevations and other datum on drawings. Any discrepencies to be reported
immediately to the Landscape Architect. Any changes made without the Landscape
Architect's written consent shall be the contractor's sole responsibility. Do not scale
drawings. Dimensions govern.
Contact
Unit 206, 1493 Foster Street, White Rock, BC
604 385 3600 | ruchir@architecturepanel.com
© Architecture Panel Inc. All rights reserved.