CITY OF LANGFORD - BYLAW NO. 1618 - Subdivision and Development Servicing Bylaw, Amendment No. 13

Text of Bylaw No. 1618 amending the City of Langford Subdivision and Development Servicing Bylaw (No. 1000) updating street lighting requirements, drawings and schedules.

9.a BYLAWS - BYLAW NO. 1618 "Subdivision and Development Servicing Bylaw, Amendment No. 13, Bylaw No. 1618" (ADOPTION)

Key facts

  • Bylaw No.: 1618 (Amendment No. 13 to Subdivision and Development Servicing Bylaw No. 1000)
  • Amendments include replacement of sections and drawings related to street lighting (Sections 4.18.1, 4.18.3, new drawing E8, E9, E10)
  • Specifies LED fixtures (GE Evolve model numbers ERS20E3C1540 and ERS10B3A1540) for davit ('cobra') overhead street lighting, with HPS exception
  • Readings: READ A FIRST, SECOND and THIRD TIME on March 21, 2016; adoption signed in April (adopted date line present)

CITY OF LANGFORD - BYLAW NO. 1618 - Subdivision and Development Servicing Bylaw, Amendment No. 13

The Council of the City of Langford, in open meeting assembled, enacts as follows:

  1. City of Langford Subdivision and Development Servicing Bylaw No. 1000 is amended as follows:

i) Replace Section 4.18.1 with the following: 4.18.1 All public highways and hard surfaced walkways shall have street lighting installed.

Replace Section 4.18.3 with the following: 4.18.3 All new street lighting installations shall have a controller base with a secure lockable compartment provided in accordance with the manufacturer’s specifications and as noted on Dwg. E9, unless the new street lights are connecting to an existing circuit with a controller base.

Replace Section 4.18.1.5 with the following: 4.18.1.5 The design shall not consider existing BC Hydro davit arms and are to note their removal on the design drawings.

Replace Section 4.18.13.1.5 with the following: 4.18.13.1.5 Table showing IESNA lighting design criteria and design achieved illumination levels and uniformity

Add to Section 4.18.1 the following new paragraph: 4.18.1.11 Davit (‘cobra’) overhead street lighting shall use GE Evolve light-emitting diode (LED) lighting fixtures of the following model numbers:

ERS20E3C1540
ERS10B3A1540

This requirement may be waived by the City Engineer should the lighting be installed in an area of existing high-pressure sodium (HPS) lighting. In areas where HPS lighting is required, designs are to use Philips Lumec Helios Series fixtures.

ii) Replace existing Drawing E3 with new Drawing E8 Langford Post Top Luminaire.

iii) Replace existing Drawing E4 with new Drawing E9 Langford Service Base.

iv) Replace existing Drawing E7 with new Drawing E10 Cobra Street Light.

v) Amend Schedule 11 – Supplements to MMCD table to reflect the drawing changes as follows:

Schedule 11 – Supplements to MMCD table (illustration of table changes)
Schedule 11 – Supplements to MMCD table (illustration of table changes)
  1. This Bylaw may be cited as “Subdivision and Development Servicing Bylaw, Amendment No. 13, Bylaw No. 1618”.

READ A FIRST TIME this 21st day of March, 2016.
READ A SECOND TIME this 21st day of March, 2016.
READ A THIRD TIME this 21st day of March, 2016.
ADOPTED this day of April, 2016.

MAYOR

(Certified Correct)