This site is in beta — data may be incomplete and features are still being added.

DocumentsBylawMar 21, 2016Pages 51–53

BYLAW NO. 1618 - Subdivision and Development Servicing Bylaw, Amendment No. 13, Bylaw No. 1618 (First/Second/Third Reading)

Amendment to the Subdivision and Development Servicing Bylaw (No. 1000) identified as Amendment No.13 (Bylaw No. 1618) presented for readings.

11.b BYLAWS - BYLAW NO. 1618 (Subdivision and Development Servicing Bylaw, Amendment No. 13, Bylaw No. 1618) (FIRST, SECOND AND THIRD READING)

Key facts

  • Subject: Subdivision and Development Servicing Bylaw amendment (No. 13)
  • TOC indicates First, Second and Third Reading on agenda
  • Presented as part of the March 21, 2016 agenda package (pages omitted in prompt)

CITY OF LANGFORD

Page 51–53

BYLAW NO. 1618

A BYLAW TO AMEND THE SUBDIVISION AND DEVELOPMENT SERVICING BYLAW

The Council of the City of Langford, in open meeting assembled, enacts as follows:

1. Amendments to City of Langford Subdivision and Development Servicing Bylaw No. 1000

i) Replace Section 4.18.1 with the following: 4.18.1 All public highways and hard surfaced walkways shall have street lighting installed.

Replace Section 4.18.3 with the following: 4.18.3 All new street lighting installations shall have a controller base with a secure lockable compartment provided in accordance with the manufacturer’s specifications and as noted on Dwg. E9, unless the new street lights are connecting to an existing circuit with a controller base.

Replace Section 4.18.1.5 with the following: 4.18.1.5 The design shall not consider existing BC Hydro davit arms and are to note their removal on the design drawings.

Replace Section 4.18.13.1.5 with the following: 4.18.13.1.5 Table showing IESNA lighting design criteria and design achieved illumination levels and uniformity

Add to Section 4.18.1 the following new paragraph: 4.18.1.11 Davit (‘cobra’) overhead street lighting shall use GE Evolve light-emitting diode (LED) lighting fixtures of the following model numbers:

ERS20E3C1540
ERS10B3A1540

This requirement may be waived by the City Engineer should the lighting be installed in an area of existing high-pressure sodium (HPS) lighting. In areas where HPS lighting is required, designs are to use Philips Lumec Helios Series fixtures.

ii) Replace existing Drawing E3 with new Drawing E8 Langford Post Top Luminaire.

iii) Replace existing Drawing E4 with new Drawing E9 Langford Service Base.

iv) Replace existing Drawing E7 with new Drawing E10 Cobra Street Light.

v) Amend Schedule 11 – Supplements to MMCD table to reflect the drawing changes as follows:

Bylaw No. 1574 — Amendment No. 13 to Bylaw 1618 page image
Bylaw No. 1574 — Amendment No. 13 to Bylaw 1618 page image

2. Citation

This Bylaw may be cited as “Subdivision and Development Servicing Bylaw, Amendment No. 13, Bylaw No. 1618”.

READ A FIRST TIME this day of March, 2016.
READ A SECOND TIME this day of March, 2016.
READ A THIRD TIME this day of March, 2016.
ADOPTED this day of April, 2016.

MAYOR

         (Certified Correct)  

CORPORATE OFFICER

Page 51–53
Extracted from: 20160321-Agenda-Pakg(62 pages total)